Reliability     Safety     Capacity

Solis-80K-5G

400V: 80K

80kW three-phase series string inverter adopt 9 MPPT design to provide a more flexible configuration scheme with a smaller environmental impact rate and higher generation efficiency. Anti-resonance, supporting over 6MW parallelled in one transformer, Strings intelligent monitoring, Smart I-V Curve Diagnosis supported.

80kW Three Phase Inverter

Leading Features

  • 9 MPPTs, max. efficiency 98.7%

  • > 150% DC/AC ratio
  • Compatible with bifacial modules
  • Night SVG function
  • AFCI protection, proactively reduces fire risk
  • Intelligent string monitoring,smart I-V curve scan
  • Remote firmware upgrade with simple operation
  • Built-in PID recovery for better module performance (optional)
  • Globally recognised branded componentry for longer life
  • IP66
  • DC side supports "Y" connector
  • Power line communication (PLC) (optional)
  • Supports aluminium wire access to reduce cost

Installation video

Installation video

Technical Specifications

DC Input

  • Rated voltage
    600 V
  • Start-up voltage
    195 V
  • MPPT voltage range
    180-1000V
  • Max. input current
    9*26 A
  • Max. Short Circuit current
    9*40 A
  • MPPT number
    9
  • Max.input strings number
    18

Output AC

  • Max. apparent output power
    88 kVA
  • Max. output power
    88 kW
  • Rated grid voltage
    3/N/PE, 220 V / 380 V, 230 V / 400 V
  • Rated grid frequency
    50 Hz
  • Rated grid output current
    121.6 A / 115.5 A
  • Max. output current
    133.7 A
  • Power Factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <3%

Efficiency

  • EU efficiency
    98.3%

Protection

  • Short circuit protection
    Yes
  • Output over current protection
    Yes
  • Surge protection
    DC Type I / AC Type II (AC Type I optional)
  • Grid monitoring
    Yes
  • Anti-islanding protection
    Yes
  • Strings Monitoring
    Yes
  • I/V Curve scanning
    Yes
  • Integrated PID recovery
    Optional
  • Integrated AFCI (DC arc-fault circuit protection)
    Yes(Activation required)
  • Integrated DC switch
    Yes
  • Integrated AC switch
    Optional

General Data

  • Weight
    82 kg
  • Topology
    Transformer less
  • Self consumption (night)
    <2 W
  • Operating ambient temperature range
    -30~+60℃
  • Relative humidity
    0-100%
  • Ingress protection
    IP66
  • Cooling concept
    Intelligent redundant fan-cooling
  • Max. operation altitude
    4000m

Standards

  • Grid connection standard
    G98 or G99, VDE-AR-N 4105 / VDE-AR-N 4110 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530

Features

  • AC connection
    OT terminal (max. 185 mm²)
  • Display
    LCD
  • Communication
    RS485, Optional: Wi-Fi, GPRS, PLC