Solis-(215-255)K-EHV-5G

215-255kW three-phase series string inverter have Maximum 28 strings input, support "Y" type connection in DC side. Maximum string input current 15A, support bifacial modules access. Supports anti-PID function to improve system efficiency. High-precision intelligent strings monitoring reduces fault location time.

215-255kW Three Phase Inverters

Leading Features

  • 9/12/14 MPPTs, max. efficiency 99%

  • 150% DC/AC ratio

  • High power tracking density 56MPPT/MW

  • Compatible with 500W+ bifacial modules

  • IP66

  • Built-in PID recovery for better module performance

  • Fuse free design, safe and maintenance free

  • Globally recognised branded componentry for longer life

  • Night SVG function

  • Intelligent string monitoring. Smart I-V curve scan

  • Remote firmware upgrade with simple operation

  • Power line communication (PLC) (optional)

  • DC side supports "Y" connector

  • Supports aluminium wire access to reduce cost

Installation video

Installation video

Technical Specifications

Input DC

  • Rated voltage

    1080 V
  • Start-up voltage

    500 V
  • MPPT voltage range

    480-1500 V
  • Max. input current

    9*30 A
  • Max. short circuit current

    9*50 A
  • MPPT number/Max. input strings number

    9/18

Output AC

  • Rated grid voltage

    3/PE, 800 V
  • Grid voltage range

    640-920 V
  • Rated grid frequency

    50 Hz / 60 Hz
  • Max. output current

    155.2 A
  • Power factor

    >0.99 (0.8 leading - 0.8 lagging)
  • THDi

    <3%
  • DC injection current

    <0.5% In

Efficiency

  • EU efficiency

    98.8%

Protection

  • Short circuit protection

    Yes
  • Output over current protection

    Yes
  • Surge protection

    DC Type II / AC Type II
  • Grid monitoring

    Yes
  • Anti-islanding protection

    Yes
  • Temperature protection

    Yes
  • Strings monitoring

    Yes
  • I/V Curve scanning

    Yes
  • Night time SVG function

    Yes
  • Integrated PID recovery

    Yes
  • Integrated DC switch

    Yes

General Data

  • Weight

    109 kg
  • Topology

    Transformerless
  • Self-consumption (night)

    <2 W
  • Operating ambient temperature range

    -30 ~ +60°C
  • Relative humidity

    0-100%
  • Ingress protection

    IP66
  • Noise emission (typical)

    ≤65 dB(A)
  • Cooling concept

    Intelligent redundant fan-cooling
  • Max. operation altitude

    4000 m
  • Safety/EMC standard

    IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4
  • Grid connection standard

    EN50549, G99, AS4777.2, VDE0126, IEC61727, VDE4110, CEA 2019

Features

  • AC connection

    OT terminal (max. 300 mm²)
  • Display

    LCD
  • Communication

    RS485, Optional: PLC