S6-EH1P(3-6)K-L-PRO

3K/3.6K/5K/6K

S6-EH1P(3-6)K-L-PRO series energy storage inverter is designed for residential PV energy storage system,Support multiple parallel machines to form a single-phase or three-phase system with maximum power of 36kW. With UPS level switching time, 10s surge power overload and critical loads. Support 135A Charge and discharge capacity, provide higher energy throughput density. A variety of intelligent protection functions make home power supply safe and secure.

Energy Storage Inverter

Leading Features

  • Automatic UPS switching

  • Up to 135A max charge/discharge current

  • 6 customisable charge/discharge time settings

  • 10 second 200% surge power backup overload capability

  • Supports 1ph and 3ph flexible connection with max 36kW in parallel

  • Supports peak shaving control in both "self-use" and "generator" mode

  • Generator connectivity with multiple input methods and automatic generator On/Off control

  • Compatible with lead-acid and lithium batteries, with multiple battery protection features

Installation video

Installation video

Technical Specifications

Input DC (PV side)

  • Max. input voltage
    600 V
  • Rated voltage
    330 V
  • Start-up voltage
    90 V
  • MPPT voltage range
    90-520 V
  • Max. input current
    16 A / 16 A
  • Max. short circuit current
    24 A / 24 A
  • MPPT number/Max. input strings number
    2/2

Battery

  • Battery voltage range

    40-60 V
  • Max. charge / discharge power

    6 kW
  • Max. charge / discharge current

    135 A
  • Communication

    CAN/RS485

Output AC (Grid side)

  • Max. apparent output power
    6.6 kVA
  • Operation phase
    1/N/PE
  • Rated grid voltage
    220 V / 230 V
  • Rated grid frequency
    50 Hz / 60 Hz
  • Rated grid output current
    27.3 A / 26.1 A
  • Max. output current
    30 A
  • Power factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <2%

Input AC (Grid side)

  • Max. input current
    40 A
  • Frequency range
    45-55 Hz / 55-65 Hz

Output AC (Back-up)

  • Max. apparent output power

    2 times of rated power, 10 s
  • Back-up switch time

    <4 ms
  • Rated output voltage

    1/N/PE, 220 V / 230 V
  • Rated frequency

    50 Hz / 60 Hz
  • Rated output current

    27.3 A / 26.1 A
  • Max. output current

    40 A
  • THDv (@linear load)

    <2%

Efficiency

  • EU efficiency

    > 96.2%

Protection

  • Ground fault monitoring

    Yes
  • Integrated AFCI (DC arc-fault circuit protection)

    Yes (Activation required)
  • Protection class/Over voltage category

    I/II

General Data

  • Weight
    24 kg
  • Topology
    High frequency isolation (for battery)
  • Operating ambient temperature range
    -40 ~ +60°C
  • Ingress protection
    IP66
  • Cooling concept
    Natural convection
  • Max. operation altitude
    4000 m
  • Safety/EMC standard
    IEC/EN 62109-1/-2, EN 61000-6-2/-3
  • Grid connection standard
    NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA

Features

  • AC connection

    Terminal Block
  • Display

    LED + APP
  • Communication

    RS485, CAN, Optional: Wi-Fi, GPRS, LAN