Reliability    Safety    Capacity

S6-GR1P(2.5-6)K

2.5K/3K/3.6K/4K/4.6K/5K/6K

S6-GR1P(2.5-6)K series inverter is designed for residential PV plants. The maximum input current per string is 14A, which is compatible with high-efficiency modules and bi-facial modules. Compact and lightweight design, bring easy installation. The protection level is increased to IP66. Integrated AFCI function can proactively reduce the risk of fire.

2.5-6kW Single Phase Inverter

Leading Features

  • Max. efficiency 97.7%

  • String current up to 14A
  • Super high frequency switching technology
  • Wide voltage range and low startup voltage
  • 2 MPPT design with precise MPPT algorithm
  • Integrated Export Power Manager (EPM)
  • AFCI protection, proactively reduces fire risk
  • Compact and lightweight
  • Friendly and adaptable connection to the grid

Technical Specifications

Input DC

  • Max. input voltage
    550 V
  • Rated voltage
    250 V
  • Start-up voltage
    60 V
  • MPPT voltage range
    50-450 V
  • Max. input current
    14 A / 14 A
  • Max. short circuit current
    22 A / 22 A
  • MPPT number
    2
  • Max. input strings number
    2

Output AC

  • Max. apparent output power
    2.8 kVA
  • Max. output power
    2.8 kW
  • Rated grid voltage
    1/N/PE, 220 V / 230 V
  • Rated grid frequency
    50 Hz / 60 Hz
  • Rated grid output current
    11.4 A / 10.9 A
  • Max. output current
    13.3 A
  • Power factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <3%

Efficiency

  • EU efficiency
    96.5%

Protection

  • Short circuit protection
    Yes
  • Output over current protection
    Yes
  • Surge protection
    Yes
  • Grid monitoring
    Yes
  • Anti-islanding protection
    Yes
  • Temperature protection
    Yes
  • Integrated AFCI (DC arc-fault circuit protection)
    Yes (activation required.)
  • Integrated DC switch
    Optional

General Data

  • Weight
    11 kg
  • Topology
    Transformerless
  • Self-consumption (night)
    <1 W
  • Operating ambient temperature range
    -25 ~ +60°C
  • Relative humidity
    0-100%
  • Ingress protection
    IP66
  • Cooling concept
    Natural convection
  • Max. operation altitude
    4000 m
  • Safety/EMC standard
    IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3
  • Grid connection standard
    G98(G98 for 2.5K-3.6K) or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA

Features

  • AC connection
    Quick connection plug
  • Display
    LCD
  • Communication
    RS485, Optional: Wi-Fi, GPRS
Sales Inquiries:sales@ginlong.com
Copyright@2019 Ginlong Technologies All Rights Reserved
Captcha*