Ordering: S6-EH1P(3.8-11.4)K-H-US
• APST (APS MLRSD Transmitter)
• RSS (Tigo MLRSD Transmitter)
• ENT (Enteligent MLRSD Transmitter)
The S6 (Series 6) hybrid energy storage inverter is the latest Solis US model certified to IEEE 1547-2018, UL 1741 SA & SB, and SunSpec Modbus, providing economical zero-carbon power from an all-weather (NEMA 4X / IP 66) high-efficiency PV string inverter. This new PV / Battery inverter can be DC-coupled to a variety of certified high-voltage Lithium batteries. The S6 hybrid is a grid-forming inverter that supports the latest large PV modules with high current (16 amp) dc inputs at each MPPT.
Backup transfer (switch) time is < 10ms
UL 1741 SA/SB and UL 9540 certified
Maximum PV input current up to 16A per string
California Rule 21 and HECO Rule 14H compliant
Generates 120/240V backup power without an external autotransformer
DC to DC battery charging for optimal use of PVgenerated energy
External RSD & emergency power off switch options are also available
Able to supply a wide range of continuous backup power in the event of a grid outage
Generates up to 50A/114kW of continuous backup power with up to 76A for ten seconds
Compatible with multiple battery brands, providing up to 150 kWh of storage capacity per inverter
Allows up to ten (10) inverters to be stacked in parallel for maximum scalability and flexibility
SolisCloud allows for remote system troubleshooting, firmware upgrading, and configuration, reducing O&M costs
NEC 2020 compliant with various integrated RSD transmitter options are available for module-level rapid shutdown
Supports operation in parallel with a generator and allows the generator to function as the grid source if utility power is lost
Optional integrated revenue-grade meter and external energy meter for production & consumption monitoring and export power control
Max. apparent output power
Back-up switch time
Phase Power
Rated output voltage (L1-L2)
AC output voltage range
Rated grid frequency
Frequency range
Rated AC output current
Max. output overcurrent protection, 10 sec
Max. allowable phase imbalance
Backup support configurations
Power factor
THDv (@linear load)
PV CEC efficiency
BAT charged by PV Max. efficiency
BAT charged/discharged to AC Max. efficiency
Residual (leakage) current detection
Integrated AFCI (DC arc-fault circuit protection)
DC reverse-polarity protection
Rapid Shutdown NEC 2017
Compatible RSD Receivers
Protection class/Over voltage category
Manual inverter bypass switch
Weight
Topology
Self-consumption (night)
Operation temperature range
Ingress protection
Noise emission
Cooling method
Mounting type
Max. operation altitude
Compliance
Generator support
AC connection
Interface
Monitoring platform
Revenue Grade Meter
Communication
Integrated RSD Transmitter Brands